MCS1806 Hall-effect Current Sensors

Monolithic Power Systems (MPS) MCS1806 Hall-effect Current Sensors are 3kVRMS isolated current sensors with 500VRMS working voltage and ±2.5% accuracy. These linear Hall-effect current sensors for AC or DC current sensing incorporate differential Hall arrays that cancel out any stray magnetic fields. The MCS1806 current sensors feature ±5A to ±50A bidirectional range, adjustable bandwidth up to 100kHz, and ratio-metric outputs from the supply voltages. These Hall-effect sensors are available in SOIC-8 packages, which are factory-trimmed for accuracy and offer no magnetic Hysteresis. The MCS1806 Hall-effect current sensors are ideally used in multi-phase inverters, motor controls, automotive systems, Switch-Mode Power Supplies (SMPSs), over-current fault protection, and load detection and management.

Ergebnisse: 23
Auswählen Bild Teile-Nr. Herst. Beschreibung Datenblatt Verfügbarkeit Preis (EUR) Ergebnisse in der Tabelle nach dem Einheitspreis bei Ihrer Menge filtern. Menge RoHS ECAD Model Nennstrom Art des Sensors Ansprechzeit Präzision Frequenzbereich Betriebsversorgungsspannung Art der Ausgabe Maximale Betriebstemperatur Minimale Betriebstemperatur Verpackung/Gehäuse Versorgungsspannung - Max. Versorgungsspannung - Min. Typ
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 970Auf Lager
Min.: 1
Mult.: 1
: 500

30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2 453Auf Lager
Min.: 1
Mult.: 1
: 500

40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 337Auf Lager
Min.: 1
Mult.: 1
: 500

40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 533Auf Lager
Min.: 1
Mult.: 1
: 500

20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2 500Auf Lager
Min.: 1
Mult.: 1
: 2 500

20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 75Auf Lager
5 000Auf Bestellung
Min.: 1
Mult.: 1
: 2 500

5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 492Auf Lager
Min.: 1
Mult.: 1
: 500

5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 104Auf Lager
Min.: 1
Mult.: 1
: 500

20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 177Auf Lager
Min.: 1
Mult.: 1
: 500

50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 28Auf Lager
Min.: 1
Mult.: 1
: 500

10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
895Auf Bestellung
Min.: 1
Mult.: 1
: 500

5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
500erwartet ab 19.10.2026
Min.: 1
Mult.: 1
: 500

30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
498erwartet ab 08.12.2026
Min.: 1
Mult.: 1
: 500

50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Vorlaufzeit 64 Wochen
Min.: 1
Mult.: 1
: 500

10 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Nicht-auf-Lager-Vorlaufzeit 57 Wochen
Min.: 2 500
Mult.: 2 500
: 2 500

50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect